Product CodeDescription

SIZE RANGE:

DN 80-DN 600 (DN50 and DN65 also available not to AS/NZS2638.2)

ALLOWABLE OPERATING PRESSURE:

1600 kPa; 1.6 Mpa

MAXIMUM TEST PRESSURE:

2400 kPa, 2.4 Mpa

CERTIFICATION:

SAI Global

WATERMARK LIC. NO.:

25890

WSAA APPRAISAL No.

PA2106

NOTE:

Alternate Flange adaptors and Couplings are available DN355 – DN630. Please contact us for details.

Certified standard logos

Do you need to know more information about this product?

FAQ

Derwent Industries supplies PE products for High-Density Polyethylene (HDPE) piping systems across several key sectors:

  • Water & Utilities: Potable water, wastewater, fire systems, and water circulation
  • Agriculture & Commercial: Irrigation systems
  • Industrial: Mining applications
    They are designed for both above-ground and below-ground installations.
  • Body & Flange: Ductile Iron GGG450-10
  • Coating: Akzo Nobel Fusion Bonded Epoxy (compliant with AS/NZS 4158)
  • Bolts: 316 Stainless Steel for high corrosion resistance
  • Lip Seal: EPDM rubber
    Gripper Ring: Brass (Ms58)
    Spacer Bush: Polyethylene (PE)
  1. Size Verification: Confirm the coupling/adaptor matches the host pipe dimensions.
  2. Support Liners: Use an internal support liner if installing on thin-walled PE pipes (>SDR 21) under low internal pressure.
  3. Pipe Preparation: Chamfer the pipe end prior to insertion to protect the EPDM seal and assist fitting.
  4. Lubrication: Apply an approved pipe lubricant to the pipe end.
  5. Assembly: Push the pipe fully to the recommended insert depth, then tighten the locking ring bolts evenly around the fitting until secured tight against the stop.